CAUTION
Connect fixture to a 120 volt, 60 Hz power source. Any other connection voids
the warranty.
Fixture must be mounted to a grounded recessed junction box marked for use
in wet locations.
Suitable for wall mount or eave mount only. NOT suitable for ground mount installation.
Do not allow sensor head to touch light housing – maintain at least 1 inch space
between fixture and sensor.
Keep away from flammable objects. Do not position fixture within
2 inches of any combustible materials.
For proper operation and protection against damage, the motion
sensor head adjustment knobs must be facing the ground.
MINIMUM 90° C SUPPLY CONDUCTORS.
Do not use this apparatus near water.
Clean only with a dry cloth.
Do not block any ventilation openings. Install in accordance with the manufacturer’s
instructions.
Do not install near any heat sources such as radiators, heat registers, stoves or other
apparatus (including amplifiers) that produce heat.
Only use attachments/accessories specified by the manufacturer.
This device complies with Part 15 of the FCC Rules. Operation is subject to the
following two conditions: (1) This device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that
may cause undesired operation. Under Part 15 of the FCC Rules, any changes or
modifications to the motion detector described in this instruction sheet that are
not expressly approved by Cooper Lighting, LLC could void the user’s authority to
operate the equipment.
NOTE: This equipment has been tested and found to comply with the limits for
a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference in a
residential installation. This equipment generates, uses and can radiate radio
frequency energy and if not installed and used in accordance with the instructions,
may cause harmful interference to radio communications. However, there is no
guarantee that interference will not occur in a particular installation. If this equipment
does cause harmful interference to radio or television reception, which can be
determined by turning the equipment off and on, the user is encouraged to try to
correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the
receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
WARNING: FCC Regulations state that any unauthorized changes or
modifications to this equipment not expressly approved by the manufacturer
could void the user’s authorization to operate this equipment.
PACKAGING CONTENTS/CONTENIDO DEL PAQUETE
ITEMS REQUIRED
(Purchase separately)
Phillips screwdriver
Outdoor weatherproof silicone caulking
(2) 100 watt (MAX) PAR 38 floodlight bulbs
NOTE: This fixture was designed to work with up to 150 watt maximum PAR halogen flood
bulbs. For improved energy efficiency, lower wattage PAR halogen flood bulbs may be used.
Compact Fluorescent (CFL) bulbs contain electronics which may interfere with the motion
sensing function of your fixture and are not recommended. To meet ENERGY STAR
®
requirements, maximum total lamp wattage can not exceed 250 watts.
HOW IT WORKS
PIR does a good job of detecting lateral motion across the 180°
range of detection. Precision Plus Doppler Radar™ does an
excellent job detecting motion towards and away from the unit.
Both systems combined provide enhanced accuracy and complete
coverage within the detection range. Motion from any direction will
trigger your floodlight—even during hot or cold temperature extremes.
IMPORTANT SAFETY INSTRUCTIONS
When using product, basic precautions should always be followed, including the following:
Read and follow these instructions.
Heed all warnings, including below warnings AND those included on product.
Save these instructions and warnings.
For outdoor use only.
cETLus LISTED for wet location.
Suitable for wall mount or eave mount only. NOT suitable for ground mount installation.
Disassembling your fixture will void the warranty.
Your fixture is prewired and preassembled for easy installation.
Bulb gets HOT quickly!
The bulb and fixture get extremely hot during use. Disconnect power and allow fixture
to cool before changing bulb or handling fixture.
Fixture should be installed by persons with experience in household wiring or by a
qualified electrician. The electrical system, and the method of electrically connecting
the fixture to it, must be in accordance with the National Electrical Code and local
building codes.
Always replace bulb with the same wattage or lower wattage than marked. Installing
a bulb of a higher wattage could create a fire hazard. Use of a higher wattage bulb will
void the warranty. (Maximum 150 watt PAR halogen bulb.)
MS185D (Bronze)
MS185DW (White)
A. Motion detector
and light fixture
Detector de
movimiento y
artefacto de luz
ENGLISH
Up to
70 feet
180 degrees
D. (2) #6 and (2) #8 mounting screws
(use the size that fits your junction box)
(2) Tornillos #6 y (2) tornillos #8 de montaje
(utilice el tamaño que mejor se adecue a
su caja de conexión)
B. Coverplate gasket
Junta de la placa
de cubierta
E. (3) Wire nuts
(3) Conectores
de cable
C. (2) Lampholder gaskets
(2) Juntas obturadoras
del receptáculo
F. Color-matched
center hole plug
Tapón para agujero
central de color
coincidente
G. Mounting plate
screw
Tornillo para la
placa de montaje
H. Mounting bracket
Soporte de montaje
WARNING
Page view 0
1 2 3 4 5 6

Summary of Contents

Page 1 - ENGLISH

Instruction Manual/InstruccionesQuestions?/¿Preguntas? 1-800-334-6871 [email protected]• Connect fixture to a 120 volt, 60 H

Page 2

2FOR BEST RESULTS• Install the motion sensor/transmitter 8-12 feet above the ground. (Motion sensor is less sensitive above 12 feet.)• Locate mo

Page 3 - ADVERTENCIA

3 Problem Cause / Solution Light does not come on with motion at night.No power to the fixture. • Check if circuit breaker tripped. • Confi

Page 4 - PRECAUCION

4 • Dos o más unidades montadas de lado a lado (dirigidas a la misma dirección) deben estar separadas a 17´ (5,2 m) de distancia. • Dos unid

Page 5 - SELECCIONE LA FUNCIÓN DESEADA

5detector. Ajustar el ángulo cambiará el área de detección. Aquí hay algunas directrices para ayudarle a programar la unidad: • Un buen rango par

Page 6 - GARANTIA LIMITADA DE 3 AÑOS

6GARANTIA LIMITADA DE 3 AÑOSLA SIGUIENTE GARANTÍA ES EXCLUSIVA Y REEMPLAZA A TODAS LAS DEMÁS GARANTÍAS, YA SEAN IMPLÍCITAS, EXPLÍCITAS O ESTATUTARIAS,

Comments to this Manuals

No comments